UV Compact Universal Flame Detector IFC 50

The IFC 50 is a compact UV flame detector, which is specially designed for severe condi-tions often experienced in industrial applications for single flame combustion. The IFC 50 can be connected directly to the ionisation or LDR input of the control box. The UV sensor ensures that the flame detector does not react to background radiation from hot refractory or from any other infrared light source.

The Flame detector has to be disconnected started up once in a day. For safety reasons and technical regulations a controlled burner shut down at least once per 24 hours must be guaranteed.

The flame detector IFC 50 has been developed to meet the requirements of UL 372-2, CSA C22.2 and EN 298. The internal 15 % increase of the UV tube voltage during the start-up phase ensures the safety requirement for the examination of the UV tube to through-ignition. The flame detector IFC 50 has to be switched off for more than 5 seconds before burner operation can be started again.

With the Dioptric holder, which serves also as a connection interface of the flame detector to the combustion chamber, the IFC 50 can be fitted with different glasses and lenses to special requirements. The flame detector is equipped with an optical interface which visibly indicates the flame signal intensity. A simple diagnosis of the flame intensity is directly on the furnace boiler possible.


Dimensions

IFC50 Dimensions 


Technical Specifications

  • Optical features 185 to 265 nm, tolerated flame signal fades approx. 200 ms
  • Orientation axial
  • Lifetime of the tube approx. 10000 h
  • Distance to flame < 2 m
  • Input 230 V AC - 120 V AC ( optional )
  • Nominal frequency 50-60 Hz
  • Prefuse max. 1 A , slow
  • Consumption max. 18 mA
  • Operating temperature -20 to +60°C (temperatures higher than 50°C reduces life of the UV tube )
  • Operating position any position
  • Kind of protection IP 65
  • Protection class I, FELV
  • Humidity max. 95% r.H., non-condensing
  • Electrical connenction Amphenol eco|mate plug C016
  • Restart time >5s between controlled shut-down and renewed heat request